产品详情
简单介绍:
Human AGT (Angiotensinogen) CLIA Kit (STJC0000189)
详情介绍:
Applications: | CLIA |
Reactivity: | Human |
Note: | FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: | 0.19ng/mL |
Detection Limit: | 0.31~20ng/mL |
Short Description: | This human AGT kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: | If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: | 3.5h |
Detection: | Chemiluminescence |
Gene Symbol: | AGT |
Gene ID: | 183 |
Uniprot ID: | ANGT_HUMAN |
Specificity: | This kit recognizes Human AGT in samples. No significant cross-reactivity or interference between Human AGT and analogues was observed. |
Sample Type: | Serum, plasma and other biological fluids |
Tissue Specificity | Expressed by the liver and secreted in plasma. |
Post Translational Modifications | Beta-decarboxylation of Asp-34 in angiotensin-2, by mononuclear leukocytes produces alanine. The resulting peptide form, angiotensin-A, has the same affinity for the AT1 receptor as angiotensin-2, but a higher affinity for the AT2 receptor. In response to low blood pressure, the enzyme renin/REN cleaves angiotensinogen to produce angiotensin-1. Angiotensin-1 is a substrate of ACE (angiotensin converting enzyme) that removes a dipeptide to yield the physiologically active peptide angiotensin-2. Angiotensin-1 and angiotensin-2 can be further processed to generate angiotensin-3, angiotensin-4. Angiotensin 1-9 is cleaved from angiotensin-1 by ACE2 and can be further processed by ACE to produce angiotensin 1-7, angiotensin 1-5 and angiotensin 1-4. Angiotensin 1-7 has also been proposed to be cleaved from angiotensin-2 by ACE2 or from angiotensin-1 by MME (neprilysin). The disulfide bond is labile. Angiotensinogen is present in the circulation in a near 40:60 ratio with the oxidized disulfide-bonded form, which preferentially interacts with receptor-bound renin. |
Function | Essential component of the renin-angiotensin system (RAS), a potent regulator of blood pressure, body fluid and electrolyte homeostasis. Angiotensin-2: Acts directly on vascular smooth muscle as a potent vasoconstrictor, affects cardiac contractility and heart rate through its action on the sympathetic nervous system, and alters renal sodium and water absorption through its ability to stimulate the zona glomerulosa cells of the adrenal cortex to synthesize and secrete aldosterone. Acts by binding to angiotensin receptors AGTR1 and AGTR2. Also binds the DEAR/FBXW7-AS1 receptor. Angiotensin-3: Stimulates aldosterone release. Angiotensin 1-7: Is a ligand for the G-protein coupled receptor MAS1. Has vasodilator and antidiuretic effects. Has an antithrombotic effect that involves MAS1-mediated release of nitric oxide from platelets. |
Protein Name | Angiotensinogen Serpin A8 Cleaved Into - Angiotensin-1 Angiotensin 1-10 Angiotensin I Ang I - Angiotensin-2 Angiotensin 1-8 Angiotensin Ii Ang Ii - Angiotensin-3 Angiotensin 2-8 Angiotensin Iii Ang Iii Des-Asp1-Angiotensin Ii - Angiotensin-4 Angiotensin 3-8 Angiotensin Iv Ang Iv - Angiotensin 1-9 - Angiotensin 1-7 - Angiotensin 1-5 - Angiotensin 1-4 |
Database Links | Reactome: R-HSA-1989781 Reactome: R-HSA-2022377 Reactome: R-HSA-375276 Reactome: R-HSA-416476 Reactome: R-HSA-418594 |
Cellular Localisation | Secreted |
Alternative CLIA Names | Angiotensinogen CLIA kit Serpin A8 Cleaved Into - Angiotensin-1 CLIA kit Angiotensin 1-10 CLIA kit Angiotensin I CLIA kit Ang I - Angiotensin-2 CLIA kit Angiotensin 1-8 CLIA kit Angiotensin Ii CLIA kit Ang Ii - Angiotensin-3 CLIA kit Angiotensin 2-8 CLIA kit Angiotensin Iii CLIA kit Ang Iii CLIA kit Des-Asp1-Angiotensin Ii - Angiotensin-4 CLIA kit Angiotensin 3-8 CLIA kit Angiotensin Iv CLIA kit Ang Iv - Angiotensin 1-9 - Angiotensin 1-7 - Angiotensin 1-5 - Angiotensin 1-4 CLIA kit AGT CLIA kit SERPINA8 CLIA kit |
Specificity | This kit recognizes Human AGT in samples. No significant cross-reactivity or interference between Human AGT and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Serum(n=8) | 87-101 | 94 |
EDTA plasma(n=8) | 100-115 | 108 |
Cell culture media(n=8) | 100-113 | 107 |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 0.96 | 2.83 | 7.58 | 0.92 | 2.68 | 6.97 |
Standard deviation | 0.10 | 0.28 | 0.86 | 0.08 | 0.23 | 0.70 |
CV (%) | 10.42 | 9.89 | 11.35 | 8.70 | 8.58 | 10.04 |
相关信息

- 细胞培养玄学-MRC-5细胞 2025-01-07
- Ocean NanoTech定制的详细步骤 2021-10-31
- click chemistry tools数据结果比... 2021-10-31
- Abbiotec代理的产品得到重复验证2020 2021-10-31
- LaysanBio代理商相关文献资料2020 2021-10-31
- zyagen Laboratories代理的产品得到... 2021-06-20
- Toxin Technologies代理商相关文献资... 2021-03-14
- 热烈祝贺玉博生物正式代理biocolor公司试剂产品... 2021-03-14
- 热烈祝贺玉博生物正式代理cytognos公司试剂产品... 2021-03-14
- Gelest代理的产品得到重复验证2020 2021-03-14